Low-Earth-orbit stations like the ISS survive at 75–85% recovery because cargo ships resupply water and oxygen. For 100 pioneers at Arcadia Planitia, gross water turnover exceeds 1,273 metric tons over 480 Sols.
Architectural Decision: Anatolia-LifeCore closes the water loop at ≥98.5% and the respiratory oxygen loop at ≥96.0%, relying on KOM-01.4 RodWell glacial wells only for the ~38 kg/Sol (1.5%) unavoidable makeup.
This specification details the 100-crew NASA STD-3001 metabolic matrix, 57 kPa (34% O₂) alveolar physiology, 4BMS Zeolite + 1,050 °C Methane Pyrolysis O₂ closure, 1,800 RPM VCD + BPA distillation, TCCS trace scrubbing, and the Python ECLSS controller.
1. 100-Crew Stochastic Metabolic Mass Balance (NASA STD-3001)
Daily (1 Sol ≈ 88,775 s) basal and active EVA metabolic inputs and outputs for 100 crew members are locked to NASA STD-3001 / BVAD baselines:
| Metabolic Parameter | Per Crew (kg/Sol) | 100-Crew Total (kg/Sol) | 480-Sol Cumulative (t) | Responsible Subsystem |
|---|---|---|---|---|
| Oxygen (O₂) Consumption | 0.84 kg | 84.0 kg/Sol | 40.32 t | High-Pressure PEM Electrolysis + SOXE + PBR |
| Carbon Dioxide (CO₂) Output | 1.00 kg | 100.0 kg/Sol | 48.00 t | 4BMS Zeolite CDRA + Amine Swing + Bosch/Sabatier |
| Potable & Food Prep Water | 2.90 kg | 290.0 kg/Sol | 139.20 t | Ion Exchange + Catalytic Oxidation (WPA) |
| Hygiene, Shower & Laundry | 22.50 kg | 2,250.0 kg/Sol | 1,080.00 t | Ultra/Nanofiltration + Reverse Osmosis (RO) |
| Urine + Flush Water Output | 1.60 + 0.50 kg | 210.0 kg/Sol | 100.80 t | Vapor Compression Distillation (VCD) + BPA |
| Perspiration & Respiration | 1.95 kg | 195.0 kg/Sol | 93.60 t | Condensing Heat Exchangers (CHX) |
≥98.5% closed-loop water recycling trims external RodWell glacial makeup to ~38 kg/Sol across 480 Sols.
2. 57 kPa (34% O₂) Exploration Atmosphere & Zero-Prebreathe EVA
Operating habitats at 101.3 kPa sea-level pressure imposes 10 t/m² bursting loads and forces 4-hour pure-O₂ pre-breathe protocols before EVA. The 57.0 kPa (8.2 psia), 34% O₂ Exploration Atmosphere solves both simultaneously.
Tissue nitrogen ratio TR = P_N2 / P_suit = 36.7 / 29.6 = 1.24 < 1.40 safe limit, eliminating decompression sickness during rapid suit donning.
Pioneers can don 29.6 kPa EVA suits and exit for emergency repairs within 10 minutes with zero pre-breathe delay.
At 57 kPa, 34% O₂ matches the flammability index of 23.5% O₂ at sea level; all textiles use flame-proof Nomex/Kevlar and PBI.
3. 4BMS Zeolite Scrubbing & Sabatier + 1,050 °C Methane Pyrolysis
Cabin P_CO2 is held below 2.0 mmHg (0.26 kPa) by four parallel 4BMS Zeolite 13X/5A thermal-vacuum swing units capturing 100 kg CO₂/Sol.
Recovers all hydrogen trapped in Sabatier methane, lifting O₂ closure from 50% to 96% while yielding solid pyrolytic carbon (biochar / shielding additive).
Silica gel + Zeolite 13X dry the airstream before 4 Å Zeolite 5A captures 0.33 nm CO₂; saturated beds desorb at 200 °C under vacuum.
4. ≥98.5% Water Closure (VCD + BPA), WPA & TCCS Trace Control
Under 0.38g Martian gravity, a 1,800 RPM centrifugal Vapor Compression Distillation (VCD) drum ensures clean phase separation at just 95 Wh/L.
Vacuum boiling at 35 °C recompressed to 42 °C recycles 2,400 kJ/kg latent heat; dual PTFE/Nafion BPA membranes dry residual brine to lift urine recovery from 85% to 98.5%.
0.02 µm Ti UF → RO → 130 °C Pt/Ru catalytic oxidation → 265 nm UV-C → Ca²⁺/Mg²⁺ + 400 ppb Ag⁺; air trace contaminants cleared by phosphoric-acid carbon, 400 °C Pd/Pt oxidizer, and LiOH.
5. Core Software Architecture (Anatolia-LifeCore Controller — Python)
Deterministic Python SCADA controller maintaining 57.0 kPa pressure, 34% O₂, <2.0 mmHg CO₂, and 98.5% VCD recovery for 100 crew:
"""
NeoAnatolia OS - Anatolia-LifeCore (KOM-03.1)
57 kPa (%34 O2) Exploration Atmosphere & 98.5% Closed-Loop Water/O2 Mass Balance Controller
Calisma dugumu: Mars-Central-1 ECLSS SCADA Core (ipn:401.3)
"""
from dataclasses import dataclass
from typing import Dict
@dataclass
class HabitatState:
crew_count: int = 100
habitat_volume_m3: float = 12000.0 # Yasam kubbeleri net hava hacmi (m3)
temp_kelvin: float = 295.15 # 22.0 C nominal sicaklik
total_pressure_kpa: float = 57.00 # Hedef: 57.0 kPa (8.2 psia)
p_o2_kpa: float = 19.38 # Hedef: %34.0 O2 -> 19.38 kPa
p_co2_kpa: float = 0.20 # Hedef: < 0.266 kPa (2.0 mmHg)
p_n2_ar_kpa: float = 36.12 # Tampon gaz (N2 + Ar)
p_h2o_kpa: float = 1.30 # %50 Bagil Nem
potable_water_tank_kg: float = 15000.0
wastewater_tank_kg: float = 850.0
class AnatoliaLifeCoreController:
def __init__(self, state: HabitatState):
self.s = state
self.r_specific_o2 = 0.2598 # kJ/(kg*K)
self.r_specific_co2 = 0.1889 # kJ/(kg*K)
self.vcd_recovery_eff = 0.985 # %98.5 VCD + BPA Su Geri Kazanim Verimi
def step_simulation_hour(self, active_eva_crew: int = 10, metabolic_intensity: float = 1.0) -> Dict[str, float]:
"""
1 Saatlik (1/24.66 Sol) koloni metabolik tuketimini ve ECLSS geri kazanim tepkisini hesaplar.
"""
indoor_crew = self.s.crew_count - active_eva_crew
# 1. Saatlik Metabolik Tuketim ve Uretim (kg/saat)
o2_consumed_kg = indoor_crew * (0.84 / 24.66) * metabolic_intensity
co2_produced_kg = indoor_crew * (1.00 / 24.66) * metabolic_intensity
water_used_kg = self.s.crew_count * ((2.90 + 22.50) / 24.66)
wastewater_generated_kg = self.s.crew_count * ((2.10 + 1.95 + 22.50) / 24.66)
# 2. Kabin Kismi Basinc Degisimleri (Ideal Gaz Yasasi: dP = dM * R * T / V)
dp_o2_drop = (o2_consumed_kg * self.r_specific_o2 * self.s.temp_kelvin) / self.s.habitat_volume_m3
dp_co2_rise = (co2_produced_kg * self.r_specific_co2 * self.s.temp_kelvin) / self.s.habitat_volume_m3
self.s.p_o2_kpa -= dp_o2_drop
self.s.p_co2_kpa += dp_co2_rise
# 3. 4BMS Zeolit CDRA CO2 Yikama ve Sabatier+Piroliz O2 Geri Kazanimi
co2_scrubbed_kg = 0.0
if self.s.p_co2_kpa > 0.18:
excess_p_co2 = self.s.p_co2_kpa - 0.18
co2_scrubbed_kg = (excess_p_co2 * self.s.habitat_volume_m3) / (self.r_specific_co2 * self.s.temp_kelvin)
self.s.p_co2_kpa -= excess_p_co2
# Sabatier + Metan Pirolizi + Elektroliz ile yakalanan CO2'den %96 verimle O2 uretimi
o2_recovered_from_co2_kg = co2_scrubbed_kg * 0.7272 * 0.96
# Eksik O2'yi PEM Su Elektrolizinden ve ISRU LOX rezervinden tamamla (Hedef: 19.38 kPa)
o2_deficit_p = max(0.0, 19.38 - self.s.p_o2_kpa)
o2_needed_total_kg = (o2_deficit_p * self.s.habitat_volume_m3) / (self.r_specific_o2 * self.s.temp_kelvin)
o2_makeup_electrolysis_kg = max(0.0, o2_needed_total_kg - o2_recovered_from_co2_kg)
self.s.p_o2_kpa = 19.38
self.s.total_pressure_kpa = self.s.p_o2_kpa + self.s.p_co2_kpa + self.s.p_n2_ar_kpa + self.s.p_h2o_kpa
# 4. VCD + RO Su Aritma Dongusu (%98.5 Geri Kazanim)
self.s.potable_water_tank_kg -= water_used_kg
self.s.wastewater_tank_kg += wastewater_generated_kg
processed_wastewater_kg = min(self.s.wastewater_tank_kg, 150.0)
self.s.wastewater_tank_kg -= processed_wastewater_kg
reclaimed_water_kg = processed_wastewater_kg * self.vcd_recovery_eff
self.s.potable_water_tank_kg += reclaimed_water_kg
return {
"total_pressure_kpa": round(self.s.total_pressure_kpa, 2),
"o2_fraction_pct": round((self.s.p_o2_kpa / self.s.total_pressure_kpa) * 100.0, 2),
"co2_mmhg": round(self.s.p_co2_kpa * 7.50062, 2),
"co2_scrubbed_kg_h": round(co2_scrubbed_kg, 2),
"o2_recovered_kg_h": round(o2_recovered_from_co2_kg, 2),
"o2_makeup_kg_h": round(o2_makeup_electrolysis_kg, 2),
"water_reclaimed_kg_h": round(reclaimed_water_kg, 2),
"potable_water_reserve_kg": round(self.s.potable_water_tank_kg, 1)
}
if __name__ == "__main__":
hab = HabitatState()
ctrl = AnatoliaLifeCoreController(hab)
metrics = ctrl.step_simulation_hour(active_eva_crew=8, metabolic_intensity=1.15)
print("[ANATOLIA-LIFECORE ECLSS DURUM RAPORU]")
print(f" -> Kabin Basinci: {metrics['total_pressure_kpa']} kPa | O2 Orani: %{metrics['o2_fraction_pct']} | CO2: {metrics['co2_mmhg']} mmHg")
print(f" -> Saatlik Yikanan CO2: {metrics['co2_scrubbed_kg_h']} kg | Geri Kazanilan O2: {metrics['o2_recovered_kg_h']} kg")
print(f" -> VCD/RO Geri Kazanilan Su: {metrics['water_reclaimed_kg_h']} kg/saat | Icme Suyu Rezervi: {metrics['potable_water_reserve_kg']} kg")Tracks hourly EVA and metabolic swings to balance 4BMS scrubbing and PEM electrolysis makeup automatically.